TechNote 7600-02
7610 - Preventative Maintenance Kit /
71 Ozone Filter / 72 Change Filter
17 Feb 1997 Ed Palmer

Summary: The display shows 71 OZONE FILTER or 72 CHANGE FILTER.

Cause: Printer maintenance is due. At 99,000 pages, the display will show 71 OZONE FILTER and allow 1,000 more pages to print. At 100,000 pages the display will show 72 CHANGE FILTER. Printing cannot resume until the ozone filter is replaced and the message is cleared.

Solution: The 7610 requires service every 100,000 pages by a qualified technician. The 7610 Preventative Maintenance Kit 5A2230K01 (115v) consists of the following items:

GEK-89132 Instructions
UH0783001 Fixing Unit, 115V
UH1342001 Paper Feed Roller Unit
UH0785001 Transfer Unit
UH0786001 Ozone Filter
UH1376001 Separation Pad
UH0589001 Paper Feed Roller


To reset the ozone counter:


Copyright © 2000 GENICOM,

Specifications subject to change without notice.
® All trademarks are property of their respective holders at the time of this publication.


If you have any questions or comments regarding this document, please contact
TallyGenicom Technical Support.


TallyGenicom has taken care to ensure that the information is complete, accurate and up-to-date. However, GENICOM assumes no responsibility for errors or omissions which may occur. All the information provided is subject to change from time to time at the sole discretion of GENICOM. This information is provided "as is" without warranty of any kind. GENICOM disclaims all warranties, either express or implied, including the warranties of merchantability and fitness for a particular purpose. In no event shall GENICOM, or its suppliers be liable for any damages whatsoever including direct, indirect, incidental, consequential, loss of business profits or special damages, even if GENICOM, or its suppliers have been advised of the possibility of such damages. Some states do not allow the exclusion or limitation of liability for consequential or incidental damages so the foregoing limitation may not apply.