TechNote  40U-025

4000  Series

4000 Series - HP JetDirect EX Plus
05-13-97 Ed Palmer

Models: 4410 / 4440; 4470 / 4490. All

Summary:
PROBLEM: No printing, or incorrect printing when connected to an H-P Jet Direct EX Plus, 3 EX Plus print server. The printer may ignore control codes, pause during printing, or print partial jobs.

CAUSE: Most modern parallel interfaces, including the HP JetDirect EX Plus, require that the BUSY lead toggle with each character (BUSY by character)- the older 4000 series conform to the original Centronics specification, and toggle the BUSY lead only on a full line of data (BUSY by line).


Resolution:
Change the parallel interface BUSY lead characteristics on the printer.

- 4410XT+, 4440XT+, 4470XT, 4490XT, 4810, 4840, 4910, 4940- set interface strap H-18 to 0 or OUT from the printer control panel. H-17 may also have to be set to 0 or OUT.

NOTE: The 4810, 4840, 4910, 4940, and late model 4410XT, 4440XT, 4470XT, and 4490XT default to H-18 OUT.

- 4410, 4410XT, 4440, or 4440XT with SMPI/2; 4470 or 4490 with SMPI/4 interface board- set jumper J49/J50 on the SMPI board to the J49 position. The SMPI (Shuttle Matrix Parallel Interface) board is located in the logic cage on the right side of the printer. J51/J52 may also have to be set to J51.

- 4410A or 4440A with SMPI/1- set jumper J21/J22 to the J22 position. J61/J62 may also have to be set to J61. (The control panel on the A model has a red LED display.)

- 4410, 4410XT, 4440, or 4440XT with SMPI/3; 4470 or 4490 with SMPI/5- these versions of the SMPI are DataProducts long-line interfaces, and are not Centronics compatible. These boards must be replaced with a SMPI/2 or SMPI/4 respectively.

- SMPI/6, SMPI/7, SMPI/8- these are special OEM versions of the SMPI board.

TEST: To test the connection between the HP JetDirect EX Plus and the printer:

- Connect the printer to Parallel Port 1 on the JetDirect. Only Port 1 on the JetDirect 3 EX Plus will print the test page.

- Ensure the printer is on-line.

- Press the TEST key on the JetDirect for 10 seconds.

- After about 30 seconds, the JetDirect status page should print.

- Examine the status page for any incorrect text.

- If the test page does not print correctly, there is a problem between the JetDirect and the printer.

- If the test page prints correctly, but jobs do not print correctly from the system, there is a problem between the JetDirect and the host system.

NOTES:

- This procedure will not fix problems with the 4812, 4842, 4492XT, or 4592XT. The SmartGraphics board in these models controls the interface. Interface control is set through the D strap set- refer to the IGP or Code V programmer's manual. The SmartGraphics parallel interface is BUSY by character only.

- The description of strap H-18 in some of the user's manuals is incorrect.



Specifications subject to change without notice.
® All trademarks are property of their respective holders at the time of this publication.

If you have any questions or comments regarding this document, please contact

TallyGenicom Technical Support.



TallyGenicom has taken care to ensure that the information is complete, accurate and up-to-date. However, TallyGenicom assumes no responsibility for errors or omissions which may occur. All the information provided is subject to change from time to time at the sole discretion of TallyGenicom. This information is provided "as is" without warranty of any kind. TallyGenicom disclaims all warranties, either express or implied, including the warranties of merchantability and fitness for a particular purpose. In no event shall TallyGenicom, or its suppliers be liable for any damages whatsoever including direct, indirect, incidental, consequential, loss of business profits or special damages, even if TallyGenicom, or its suppliers have been advised of the possibility of such damages. Some states do not allow the exclusion or limitation of liability for consequential or incidental damages so the foregoing limitation may not apply.