| TechNote 4440-JetDirect | ![]() |
| 4000 Series and HP JetDirect | |
| 3-17-00 Ed Palmer |
MODELS: 4410, 4440, 4410XT, 4440XT, 4410XT+, 4440XT+, 4470, 4490, 4470XT, 4490XT
SUMMARY: No printing, or incorrect printing when connected to an HP Jet Direct external print server. The printer may ignore control codes, double print, pause during printing, or print partial jobs.
NOTE: Please read this entire note to determine the appropriate solution.
CHECK: To test the connection between the JetDirect and the printer:
THE PRESENT CONFIGURATION IS: ASIC (44Axxxxxx ER - 44Axxxxxx IS)
Set interface strap H-18 to 0 or OUT from the printer control panel. H-17 may also have to be set to 0 or OUT.
4470XT, 4490XT
Set interface strap H-18 to 0 or OUT from the printer control panel. H-17 may also have to be set to 0 or OUT.
4410, 4410XT, 4440, 4440XT, 4470, 4490
These printers have the SMPI (Shuttle Matrix Parallel Interface) board located in the logic cage in the right side
of the printer.
![]() |
SMPI/1: 4410A, 4440A Set jumper J21/J22 to the J22 position. J61/J62 may also have to be set to J61. |
| SMPI/2: 4410, 4410XT, 4440, 4440XT Set jumper J49/J50 on the SMPI board to the J49 position. J51/J52 may also have to be set to J51. |
|
| SMPI/3: 4410, 4410XT, 4440, 4440XT This version of the SMPI is a DataProducts long-line interface, and is not CENTRONICS compatible- it must be replaced with a SMPI/2. |
|
| SMPI/4: 4470, 4490 (may possibly be found in 4410, 4410XT, 4440, 4440XT) Set jumper J49/J50 on the SMPI board to the J49 position. J51/J52 may also have to be set to J51. |
|
| SMPI/5: 4470, 4490 (may possibly be found in 4410, 4410XT,
4440, 4440XT) This version of the SMPI is a DataProducts long-line interface, and is not CENTRONICS compatible- it must be replaced with a SMPI/4. |
|
| SMPI/6, SMPI/7, SMPI/8: These are special versions of the SMPI board. Contact GENICOM for further help. |
SOLUTION: Ensure the printer is set to the CENTRONICS parallel interface- refer to the printer manual.
For the 4410, 4410XT, 4440, 4440XT, 4470, 4490, ensure the SMPI/2 or SMPI/4 board is strapped
for CENTRONICS by setting the following jumpers:
J2, J3, J5 (may be hard-wired), J8, J10, J11, J13, J16, J21, J23, J25, J27, J29, J31, J33, J35, J37, J39, J41,
J43, J45, J47, J49, J51, J53, J55, J58, J60, J62, J63, J66, J68, J70, J71, J75, J77, J79, J82.
SOLUTION: Ensure the parallel cable is 10 feet in length
or less and is in good condition.
CAUSE: The printer configuration is corrupt.
SOLUTION: Reset the printer to factory defaults- refer
to the printer user manual.
Note: Resetting the printer will set all settings to factory default.
CAUSE: The JetDirect is set to an incompatible parallel
mode.
SOLUTION: Set the JetDirect to CENTRONICS parallel mode with JetAdmin:
Note: This will reset all network configurations, including IP address.
|
Specifications subject to change without notice. ® All trademarks are property of their respective holders at the time of this publication. If you have any questions or comments regarding this document, please contact TallyGenicom Technical Support. TallyGenicom has taken care to ensure that the information is complete, accurate and up-to-date. However, TallyGenicom assumes no responsibility for errors or omissions which may occur. All the information provided is subject to change from time to time at the sole discretion of TallyGenicom. This information is provided "as is" without warranty of any kind. TallyGenicom disclaims all warranties, either express or implied, including the warranties of merchantability and fitness for a particular purpose. In no event shall TallyGenicom, or its suppliers be liable for any damages whatsoever including direct, indirect, incidental, consequential, loss of business profits or special damages, even if TallyGenicom, or its suppliers have been advised of the possibility of such damages. Some states do not allow the exclusion or limitation of liability for consequential or incidental damages so the foregoing limitation may not apply. |
|
|