4410 / 4440 SERIES SETUP PROCEDURES |
|
4410 / 4440 PRINTR CONTROL STRAPS
Detailed information in User's Manual,
pp. H4 - H5 (std. model) or H6 - H8 (XT model)
1. Take printer off-line.
2. Press PRG (Program) key. Program menu will print.
3. Press "8" (Set TOF) key. Program menu prints:
Printer Control Straps:
0. Exit
1. Printer Straps A
2. Printer Straps B
4. Press the number for the strap set you wish to modify.
Display shows: "01o" (Set A selected); or
"33o" (Set B selected) Note: small "o" might be
a small "1", depending on setting.
5. Operable keys are: (Shown in menu printout when strap set selected).
Key 0 - Save/review Changes (this doesn't print out)
Key 1 - Set Strap IN
Key 2 - Set Strap OUT
Key 3 - Forward Without Change
Key 4 - Reverse Without Change
6. Use Key 3 to advance to strap settings to change; use Keys 1/2 to
set straps in/out; and use Key 0 to review your changes. (This will
print a new strap listing.
7. When finished, Press "0" Key to return to menu. Press "0" key
again to return to offline mode; or select other options to change.
Note: Strap Set B will display as numbers 33-64; while the
printed listing and the book will refer to them as B01 - B32.
You must subtract "32" from the displayed number to determine
which strap you are changing. Fortunately, the charts in the
book will list BOTH numbers.
|
|
Specifications subject to change without notice. ® All trademarks are property of their respective holders at the time of this publication. If you have any questions or comments regarding this document, please contact TallyGenicom Technical Support. TallyGenicom has taken care to ensure that the information is complete, accurate and up-to-date. However, TallyGenicom assumes no responsibility for errors or omissions which may occur. All the information provided is subject to change from time to time at the sole discretion of TallyGenicom. This information is provided "as is" without warranty of any kind. TallyGenicom disclaims all warranties, either express or implied, including the warranties of merchantability and fitness for a particular purpose. In no event shall TallyGenicom, or its suppliers be liable for any damages whatsoever including direct, indirect, incidental, consequential, loss of business profits or special damages, even if TallyGenicom, or its suppliers have been advised of the possibility of such damages. Some states do not allow the exclusion or limitation of liability for consequential or incidental damages so the foregoing limitation may not apply. |
|
|