Summary:
User's Manual GEK-88705 contains inaccurate description of SMPI/4 jumper J73/74.


Resolution:


The 4470 / 4490 User's Manual GEK-88705 states that the SMPI/4 jumper J73/74 
is a spare jumper. This is not true. J74 should be installed if the SMPI/4 board 
is to be used in a 4470 or 4490. J73 should be installed if the SMPI/4 board is 
to be used in a 4410 or 4440.

SMPI/2 boards can only be used in a 4410 or 4440. J73/74 on a SMPI/2 board is not used.



Specifications subject to change without notice.
® All trademarks are property of their respective holders at the time of this publication.

If you have any questions or comments regarding this document, please contact

TallyGenicom Technical Support.



TallyGenicom has taken care to ensure that the information is complete, accurate and up-to-date. However, TallyGenicom assumes no responsibility for errors or omissions which may occur. All the information provided is subject to change from time to time at the sole discretion of TallyGenicom. This information is provided "as is" without warranty of any kind. TallyGenicom disclaims all warranties, either express or implied, including the warranties of merchantability and fitness for a particular purpose. In no event shall TallyGenicom, or its suppliers be liable for any damages whatsoever including direct, indirect, incidental, consequential, loss of business profits or special damages, even if TallyGenicom, or its suppliers have been advised of the possibility of such damages. Some states do not allow the exclusion or limitation of liability for consequential or incidental damages so the foregoing limitation may not apply.