TechNote 49U-001

4490  Series

4470/4490 - DataProducts to CENTRONICS Parallel Conversion
8/7/96 Ed Palmer

Models: 4470 or 4490 with SMPI parallel interface board.

Summary:


Resolution:


MODELS:  4470 or 4490 with SMPI parallel interface board.
- Replace the interface cable with 44C506014-G27.

- Check the SMPI revision:
	- The SMPI/4 is both CENTRONICS and DataProducts ShortLine parallel.
	- The SMPI/5 is DataProducts LongLine parallel only.

	- If a SMPI/5 is installed, it must be replaced with a SMPI/4 [44C502591-G04)

- Change the SMPI jumpers from the DataProducts positions to the CENTRONICS positions.
  Refer to the user's manual or the service manual.

- Set the printer emulation as desired.

MODELS:  4470XT or 4490XT with SPIO parallel interface board.
- Disconnect the DPLL board from the motherboard- remove if desired.

- Replace the interface cable with  44C506014-G27.

- Set the printer emulation as desired.



Specifications subject to change without notice.
® All trademarks are property of their respective holders at the time of this publication.

If you have any questions or comments regarding this document, please contact

TallyGenicom Technical Support.



TallyGenicom has taken care to ensure that the information is complete, accurate and up-to-date. However, TallyGenicom assumes no responsibility for errors or omissions which may occur. All the information provided is subject to change from time to time at the sole discretion of TallyGenicom. This information is provided "as is" without warranty of any kind. TallyGenicom disclaims all warranties, either express or implied, including the warranties of merchantability and fitness for a particular purpose. In no event shall TallyGenicom, or its suppliers be liable for any damages whatsoever including direct, indirect, incidental, consequential, loss of business profits or special damages, even if TallyGenicom, or its suppliers have been advised of the possibility of such damages. Some states do not allow the exclusion or limitation of liability for consequential or incidental damages so the foregoing limitation may not apply.