TechNote  48U-002

4800  Series

4800 Series VFU Command Does Not Work
7/24/96 Ed Palmer

Models: 4810, 4840

Summary:
PROBLEM: The VFU Skip to Channel command ESC [ p1 ; p2; ! p does not work.

CAUSE: There is an error in the manual GEK-89025, pg 1-30


Resolution:


SOLUTION: The VFU Skip to Channel command should be:

	ESC [ p1 ! p     where p1 is the channel.

NOTES:

-  The ESC [ p1 ; p2 ! p sequence is valid only if the printer is in 
   4000 compatibility mode.


Specifications subject to change without notice.
® All trademarks are property of their respective holders at the time of this publication.

If you have any questions or comments regarding this document, please contact

TallyGenicom Technical Support.



TallyGenicom has taken care to ensure that the information is complete, accurate and up-to-date. However, TallyGenicom assumes no responsibility for errors or omissions which may occur. All the information provided is subject to change from time to time at the sole discretion of TallyGenicom. This information is provided "as is" without warranty of any kind. TallyGenicom disclaims all warranties, either express or implied, including the warranties of merchantability and fitness for a particular purpose. In no event shall TallyGenicom, or its suppliers be liable for any damages whatsoever including direct, indirect, incidental, consequential, loss of business profits or special damages, even if TallyGenicom, or its suppliers have been advised of the possibility of such damages. Some states do not allow the exclusion or limitation of liability for consequential or incidental damages so the foregoing limitation may not apply.